Meeting WIPO ST.26 for primers, probes, antibodies and assay panels

Introduction

In vitro diagnostic (IVD) inventions are frequently defined by biological sequences. A PCR assay is characterized by its primer and probe sets; an immunoassay by the amino acid sequences of its antibodies, antigens or epitopes; a CRISPR-based test by its guide RNAs; a sequencing-based diagnostic by the target regions and barcodes it uses. Because sequences are so central, the way they are disclosed, formatted and numbered has direct consequences for the filing date, the scope of the claims and the validity of the resulting patent.

Since July 1, 2022, the worldwide framework for sequence listings has been WIPO Standard ST.26, which replaced the long-used ST.25 text format with an XML-based listing. This article explains what ST.26 requires, how it applies to the sequence types common in IVD applications, the practical traps for primers, probes and modified oligonucleotides and a workflow for preparing compliant listings in the United States, Europe and under the PCT.

The Regulatory Framework

Office or systemGoverning rulesKey points
WIPO / PCTWIPO Standard ST.26; Annex C of the Administrative Instructions under the PCTApplies to international applications filed on or after July 1, 2022; the listing is provided as an XML file and is not counted toward the page count for fees
USPTO37 CFR 1.831 to 1.835 (for applications filed on or after July 1, 2022); 37 CFR 1.821 to 1.825 continue to govern earlier ST.25-based filingsST.26 XML listing filed through Patent Center; amendments must not introduce new matter
EPORule 30 EPC and the President’s decision implementing ST.26ST.26 for applications filed on or after July 1, 2022; a missing or non-compliant listing triggers an invitation to file and late filing can carry a fee
Other officesNational implementations of ST.26Most major offices follow ST.26; confirm local transitional rules and validation tools

Why this matters for IVD. A sequence disclosed in the application but omitted from, or incorrectly represented in, the listing can lead to formal objections, delay, a later filing date for the listing and, in the worst case, disputes over what was actually disclosed on the filing date. Diagnostic patents also tend to be asserted in crowded fields where claim scope turns on the exact sequences recited.

What Must Be Included in the Sequence Listing

ST.26 requires a listing for every sequence that meets the standard’s thresholds, wherever it appears in the application: in the description, the claims, the drawings or the abstract. The principal thresholds are summarized below.

Sequence typeThreshold for inclusionTypical IVD examples
Nucleotide sequencesTen or more specifically defined nucleotidesPCR primers and probes, target amplicons, aptamers, guide RNAs, adaptors and barcodes, SNP-containing regions
Amino acid sequencesFour or more specifically defined amino acidsAntibody variable regions and CDRs, antigen and epitope peptides, enzymes used in assays, reference peptides for mass spectrometry
Sequences below the thresholdNot included in the listingShort oligonucleotides (fewer than ten defined bases) and peptides (fewer than four defined residues) are described in text without SEQ ID NOs

“Specifically defined” matters. Positions represented by a wildcard (for example, “n” in a nucleotide or “X” in an amino acid) do not count toward the threshold, so a degenerate primer must be assessed on its defined positions. Conversely, a sequence that is shorter than the threshold may still need to be listed if it is part of a longer sequence that crosses it. The test is applied to each sequence as disclosed, not to the whole molecule or the whole panel.

Sequences that appear only in figures, such as gel images, alignment diagrams and plasmid maps, are still within scope when they meet the thresholds. Applicants should also be careful that every sequence cited in claims uses the same SEQ ID NO as in the listing and the description and that references to prior-art sequences are made by public database accession number only when the sequence is not itself disclosed in the application.

Key Features of ST.26

IVD-Specific Challenges

Primers, probes and labels

Many IVD primers and probes carry chemical labels such as fluorophores and quenchers, or other conjugates (biotin, minor-groove binders). These are not nucleotide residues. The listing represents the sequence of the oligonucleotide and the label is typically described in the specification and, where the standard permits, in an annotated feature or note. Applicants should make sure the claims and description state the labels clearly, because the listing will not do that work for them.

Modified and non-natural chemistries

Locked nucleic acids, 2′-O-methyl RNA, phosphorothioate linkages, inosine, peptide nucleic acids and other analogs are common in assay design. ST.26 allows certain modified bases to be annotated from a controlled list, while chemistries outside the standard’s list or not representable as an unbranched sequence require careful treatment, often through unspecified residues with explanatory annotations. The drafting choice influences both compliance and how the claims will later be read. Review each analog against the current standard and its annexes and record how it was represented.

Degenerate and mixed primers

Respiratory panels, genotyping assays and pathogen detection kits often use degenerate primers that stand for a family of sequences. These may be represented with IUPAC ambiguity codes where permitted. Applicants must decide whether to list the degenerate sequence as a single entry, list the individual variants as separate entries, or both, based on how the claims recite them. Listing each variant that the claims separately rely on can improve written-description support and later enforcement.

Panels with many sequences

A multiplex assay may involve dozens or hundreds of primer and probe sequences. Establish a numbering convention early, record the mapping between internal names and SEQ ID NOs in a controlled spreadsheet and rely on it for the description, claims and tables so the numbering cannot drift between drafts.

Antibody-based diagnostics

Immunoassay applications often disclose antibody heavy and light chain variable regions, individual CDRs and antigen sequences. Each distinct sequence of four or more defined amino acids needs its own entry. Where claims recite CDRs by sequence or by percentage identity to a listed sequence, ensure the base sequences are in the listing and the relationships are clear.

Variants, polymorphisms and percentage identity claims

Claims that recite “at least 90% identity to SEQ ID NO: X” or a set of alleles require the reference sequence and each relevant allele to be properly listed. Such claims also raise written description and enablement questions under 35 U.S.C. 112 and the equivalent European provisions: the specification must show that the inventors possessed the claimed variants and enable the skilled person to use them. Supporting data (for example, performance of variants in the assay) should be in the application as filed.

Interaction with Claim Strategy and Eligibility

Sequence disclosure is one part of a larger set of strategic choices in diagnostics. In the United States, diagnostic claims face scrutiny under 35 U.S.C. 101 following Mayo Collaborative Services v. Prometheus Laboratories (2012) and Association for Molecular Pathology v. Myriad Genetics (2013); claims to specific, non-natural compositions such as engineered primers, probes or kits and to concrete assay methods that go beyond observing a natural correlation, are generally on firmer ground than claims directed to a correlation itself. In Europe, diagnostic method claims face different exclusions and the focus is typically on technical character and inventive step. In both regions, the sequence listing should support the whole range of claim formats you may need, because new matter cannot be added after filing.

A Workflow for Compliant Listings

  1. Inventory sequences early. While drafting, build a master list of every nucleotide and amino acid sequence in the description, claims, tables and figures, with its length, molecule type, organism and any modifications.
  2. Apply the thresholds. Decide which sequences meet the ten-nucleotide and four-amino-acid thresholds, counting only specifically defined residues and flag borderline cases for attorney review.
  3. Generate the XML using validated software. Use WIPO Sequence or another tool that implements the current version of the standard, rather than hand-editing XML.
  4. Validate before filing. Run the validator, resolve errors and warnings and have a second person compare the listing against the description and claims for SEQ ID NO consistency.
  5. Check cross-references. Verify every “SEQ ID NO:” cited in the specification, claims, tables and figures appears in the listing and refers to the intended sequence.
  6. File correctly. Submit the XML as a separate file in the correct document category through the office’s electronic filing system and confirm it passed the office’s own validation.
  7. Audit after filing. Review the filing receipt and any notices and respond promptly to any notice requiring a corrected or missing listing, keeping in mind the no-new-matter requirement for later submissions.

Priority, Continuations and the ST.25 Legacy

Families that began before July 1, 2022 may have parent applications with ST.25 listings while new filings must use ST.26. Converting a listing is not a mechanical step: sequences that were excluded or represented differently under the old standard may now need entries and the converted listing must not add new matter relative to the earlier disclosure. When a continuation, divisional or national-phase entry is filed on or after the transition date, plan the conversion as a discrete task, document any differences and be prepared to provide the statements the office requires. Where the same sequences are filed in multiple jurisdictions, keep the numbering identical so that priority and equivalence arguments are straightforward.

Common Errors and How to Avoid Them

Checklist

Conclusion

For IVD applicants, the sequence listing is part of the invention’s disclosure, not an administrative attachment. A disciplined process (early inventory, correct threshold analysis, careful handling of labels and modifications, validated XML and rigorous cross-checking against the claims) protects the filing date, supports claim scope and avoids avoidable delay. Teams that treat ST.26 as a drafting-stage task rather than a filing-day task will find that compliance becomes routine and that their diagnostic patents rest on a clean, defensible record.